Denon RCD-N8 Power Supply Kit

£13.95

Symptoms: Dead, no standby light

Cause: Failure of standby circuit IC871 overheated

Remedy: Check and replace the following components

Kit Contents: 12 piece component Kit. ● R872/873/874 have been upgraded by the manufacturer to prevent failure of IC871.

    1 x IC871, ICE3BR1765J
    1 x D871, UF4007
    1 x D872, SMD Diode
    1 x D874, SMD Diode
    1 x C874, 47uf Capacitor
    1 x C875, 0.47uF Capacitor
    1 x R872, Resistor ● Upgraded
    1 x R873, Resistor ● Upgraded
    1 x R874, Resistor  Upgraded
    1 x D873, Zener Diode
    1 x SJ11, SMD 0R0 Link
    1 x PC871, SMD Optocoupler